Quick Answer / Summary: Mount a coax and Ethernet plate on a 54 mm deep box, keep the coax at least 50 mm from any AC run, and bond the coax shield to ground at the entry point only. Use a feed-through barrel for the lowest loss and a keystone F jack where the termination must be serviceable. A steel plate in front of a wall-mounted TV can cost more than 10 dB of 2.4 GHz signal at the TV, so use plastic unless the room needs shielding.
A combination plate fails for a mechanical reason before it fails electrically. A Cat6 keystone needs about 25 mm of rear depth to hold its bend radius, an F barrel needs another 10 mm behind it, and a single-gang box is only 38 mm deep inside. Add a 6.5 mm coax and a 6 mm data cable and the box is full. The plate then closes on a crushed pair.
Two Signals in One Box
The coax side carries a 75 ohm RF signal from 54 MHz to 1002 MHz, measured in dBmV. The data side carries a 100 ohm balanced pair at 250 MHz for Cat6. They share nothing but the box, and the box is where they touch.
RF leaking into a pair shows up as retransmits or a link that trains at 100 Mbps instead of 1 Gbps. Data noise on the RF line shows up as a few noisy channels low in the band.
Box Depth and Bend Radius
Cat6 needs a bend radius of about four times its diameter, so 25 mm. A 38 mm box leaves 12 mm behind a keystone once the connector body is seated, which is not enough when the cable is folded into a corner. Use a 54 mm box or a mud ring on a deep box.
Port Count and Fill
Count ports before ordering. Two coax and two data ports need a two-gang opening, the same rule that applies to any Ethernet wall plate with more than two ports. A one-gang plate with four ports forces both cables into one clamp and leaves one under tension.
Separation, Grounding and Shield Continuity
Separation and grounding are separate rules and both matter. The table compares common plate builds; rear depth and port count decide whether the plate closes without crushing a cable.
Why the Shield Must Stay Bonded
The coax shield carries the return current and the RF reference. If the plate interrupts it, the drop behaves like an antenna and the modem sees ingress on the return band. A feed-through barrel keeps the shield continuous; a keystone F jack adds one splice, about 0.3 dB, and one more corrosion point.
Grounding at the Entry Point
Bond the coax shield to the building ground at the cable entry, per local electrical code, and nowhere else. A second bond creates a loop, and the loop current appears as hum bars in the picture or a raised noise floor at the modem. The same loop appears when a coax port shares a box with an HDMI wall plate with Ethernet, because both shields reach ground by different routes.
| Plate build | Coax method | Ports | Rear depth | Shield path |
|---|
| Feed-through combo | F barrel, snap in | 1 coax + 2 data | 25 mm | Barrel body |
| Keystone combo | F keystone jack | 1 coax + 2 data | 35 mm | One splice |
| Steel combo | F barrel + keystone | 2 coax + 2 data | 30 mm | Bonded to plate |
| Plastic combo | F barrel + keystone | 1 coax + 1 data | 25 mm | Barrel only |
| Deep steel, 2 gang | F barrel + keystone | 2 coax + 2 data | 45 mm | Bonded to plate |
The Metal Plate and Wi-Fi Behind a TV
A steel plate is a shield. Mounted behind a wall-hung TV, it sits between the router and the TV radio. At 2.4 GHz the loss through steel is not a few dB; it is enough to push the TV onto a distant access point.
A plastic plate holds the same connectors and blocks nothing. Where a steel plate is required by a fit-out, an AV wall plate at the TV with only the ports in use, plus a wired data link, is the better build.
Separation From AC
Keep coax and data at least 50 mm from any AC run, and cross AC at 90 degrees when they must cross. Parallel runs at 10 mm couple dimmer noise into the pair; the symptom is a link that drops when a light is switched.
Real Installations
Two rooms where the plate, not the cable, was the fault.
Living Room Wall-Hung TV
A 55 inch TV on a 30 mm bracket had one coax and one Cat6 behind it. The original 38 mm box crushed the pair and the link trained at 100 Mbps. A 54 mm box with a plastic two-gang plate restored 1 Gbps and moved the coax barrel 60 mm from the AC outlet.
Modem and Set-Tops in a Media Closet
A steel plate with three F barrels fed a modem and two set-tops. Downstream SNR dropped 4 dB after the plate went in with its bond screw left out. Tightening the screw to the plate restored the reading, which showed the plate was part of the shield path.
Frequently Asked Questions
Can one cable feed both the coax and the Ethernet port?
No. A coax carries one 75 ohm RF line and Ethernet needs four twisted pairs. The plate is an opening for two separate cables, not a converter between them.
Does a plastic plate weaken the coax signal?
Almost nothing. A feed-through barrel adds about 0.2 dB, while cable length and splitters dominate the loss budget on the same run at 1002 MHz.
Do I need a shielded keystone for Cat6?
Only if the cable is shielded. A shielded jack on unshielded cable adds no protection and can create a ground loop through a metal plate.
Why does the link drop to 100 Mbps at the plate?
Usually the pair is untwisted too far at the keystone or crushed by a shallow box. Keep the untwisted length under 13 mm and use a deeper box.
Can the coax shield be grounded at the plate?
Only where the plate is the cable entry point. A second bond downstream creates a loop and usually adds noise instead of removing it from the line.
Related resources: Ethernet wall plate; HDMI wall plate with Ethernet; AV wall plate