HD-SDI to HDMI: The 1.485 Gbps Legacy Path
Quick answer / TL;DR: Short answer: HD-SDI carries 720p and 1080i at 1.485 Gbps, while 3G-SDI carries 1080p at 2.97 Gbps. An HD-SDI to HDMI converter handles the lower rate only; a 3G converter handles both. Choose a 3G or 12G unit if the plant may upgrade, and confirm the converter supports 1080i deinterlacing for monitoring.
Headroom is built: separator, 23 AWG copper, foil and drain.An older broadcast installation runs HD-SDI at 1.485 Gbps, and the monitor available is an HDMI display. The converter between them has to match a rate that predates 3G equipment.
The trap is that a 3G converter will usually handle HD-SDI, while an HD-SDI converter will not handle 3G, and the direction of that compatibility matters when specifying spares.
Rates and Formats
HD-SDI operates at 1.485 Gbps or 1.485/1.001 for 59.94 Hz systems. It carries 720p at 50 or 60 and 1080i at 25 or 30, and it does not carry 1080p.
That last point is why older plants run interlaced. Upgrading to progressive required 3G-SDI, which doubled the bitrate.
| Standard | Bitrate | Formats | Legacy status |
|---|
| HD-SDI | 1.485 Gbps | 720p, 1080i | common in older plant |
| 3G-SDI | 2.97 Gbps | 1080p60 | current HD |
| 6G-SDI | 5.94 Gbps | 4K30 | transitional |
| 12G-SDI | 11.88 Gbps | 4K60 | current UHD |
A converter rated only for HD-SDI will reject a 3G signal with no picture, which looks like a fault rather than a rate mismatch.
Deinterlacing for Monitoring
The HDMI display is progressive, so a 1080i signal must be deinterlaced. The converter's deinterlacer determines whether motion looks clean.
A simple weave produces combing on movement, and a motion-adaptive implementation handles it properly. This is the difference between a usable and an annoying monitor.
- Motion adaptive: best for live content
- Weave: sharp stills, combing on motion
- Bob: smooth but soft
- Film mode: for 24 fps material
- Latency: under a frame is good
For confidence monitoring, latency matters more than absolute quality. An operator needs to see the frame now, not a perfect frame slightly late.
Audio and Loop-Through
Embedded audio is de-embedded into the HDMI stream and often to analogue outputs as well. A monitor with speakers reproduces it directly.
Loop-through keeps the SDI signal available for downstream equipment. Without it, the converter terminates the chain and the next device loses its input.
Reclocking on the loop-through output restores signal quality, which matters where the run continues for another fifty metres.
Cables and Connectors
The SDI side uses 75 ohm coax with BNC connectors, and the rate decides the cable quality. A cable rated for analogue video may work at 1.485 Gbps and fail at 2.97.
HDMI side, a short certified cable is adequate because the monitor is usually close. Keep it under three metres where the converter hangs from the monitor's input.
Support the converter rather than letting it hang. A BNC under load develops an intermittent contact that is hard to find and easy to prevent.
Spares and Replacement
Where the plant is old, keep a spare converter of the correct rate. A 3G-capable unit covers both cases and costs little more than an HD-SDI-only unit.
Record the model and rate in the documentation. When the device fails, the replacement must match the plant rather than whatever is available.
Test the spare periodically. A spare that has never been powered is an assumption rather than a spare.
Where the monitor runs a colour-critical grade, check whether the converter alters the colour space. A conversion between RGB and YCbCr invalidates a calibration and is worth confirming before trusting the picture.
Real-World Applications
Legacy studio monitor
An HD-SDI camera feed reaches an HDMI monitor at the camera position, with loop-through continuing to the switcher.
Outside broadcast truck
Older equipment in the truck outputs HD-SDI, and modern monitors accept HDMI through converters at each position.
Stadium screen feed
The broadcast feed is monitored on HDMI displays in the control room, with converters at each screen.
Archive playback
A deck outputs HD-SDI and the review monitor is HDMI, with the converter providing the interface and the audio de-embed.
Action: Three Steps
First, confirm the plant's rate. A 1.485 Gbps plant needs only HD-SDI capability, and a mixed plant needs 3G.
Second, check whether loop-through is required for downstream equipment.
Third, verify deinterlacing quality on moving content rather than on a test pattern.
Related reading: SDI to HDMI converters — blogs/news/sdi-to-hdmi
Related reading: HDMI to SDI converters — blogs/news/hdmi-to-sdi-converter
Related reading: HDMI cable length limits — blogs/news/hdmi-cable-length-limit
Standards and Verification
HD-SDI is defined by SMPTE ST 292-1, which specifies 1.485 Gbps and 1.485/1.001. Payload identification in ST 352 tells receiving equipment the format carried.
The 1.001 divisor exists because 29.97 and 59.94 Hz systems are not exactly 30 and 60. A converter that ignores it produces a picture that a broadcast monitor will not lock to.
Verification: check the converter's reported input rate against the plant documentation, then confirm the monitor locks to the picture without a rolling or split image. A split image indicates a field ordering error in the deinterlacer.
Frequently Asked Questions
Does HD-SDI carry 1080p?
No. 1080p needs 3G-SDI.
Will a 3G converter handle HD-SDI?
Yes, in almost all cases.
Is loop-through needed?
Only if the signal continues downstream.
Does it carry audio?
Yes, de-embedded to HDMI and often analogue.
What about 59.94 Hz?
The converter must support the 1.001 divisor.