Quick Answer: The fibre drop from the pole or chamber to your wall is the network operator’s cable, terminated on their optical network terminal (ONT). Everything downstream of the ONT is your cabling, at your risk. Inside the premises, single-mode fibre with SC/APC or LC/UPC connectors is the norm, and the rule that decides survival is bend radius: keep 30 mm as a working minimum and never go below 15 mm even on bend-insensitive cord. Single-mode loss of about 0.35 dB per km at 1310 nm leaves ample margin for any internal run.
Fibre to the premises ends at a small box fixed inside an external wall, and that box divides two worlds with different rules. Outside it, the drop cable, the splices and the optical budget belong to the network operator. Inside it, the patch lead, the containment and the terminations belong to the occupier. Most failed installations confuse the two before anyone looks at a connector.
Where the operator’s responsibility ends
The drop is a hardened single-mode cable, usually 2 mm or 3 mm cord or a figure-of-eight assembly with a steel messenger, factory-terminated with an SC/APC plug that pushes into the ONT. The operator splices it to a known loss budget, which assumes nobody has coiled it behind a radiator.
The ONT and its power
The ONT converts light to Ethernet and needs a mains socket that stays live. A plug pulled at night is not a fault the operator fixes for free, and a socket on a switched spur is the commonest cause of a dead line after a bank holiday. Leave a 13 A outlet within a metre.
What you may disconnect
Unplugging the patch lead at the ONT is routine. Touching the incoming drop connector is not: it is the operator’s termination, the end face is exposed when you pull it, and a speck of dust can add more loss than 200 m of cable. If the drop needs moving, book the visit.
Choosing the internal fibre
Beyond the ONT you have a choice: copper Ethernet for most runs, or fibre where distance, electrical isolation or a congested duct decides it. A reel of indoor fibre cable with a tight-buffered 900 micrometre core and LSZH sheath suits the second case, because it terminates directly without a breakout kit.
Single-mode, not multimode
Internal runs are short enough that multimode looks tempting, yet single-mode still wins: transceivers cost about the same at 1 Gbit/s and 10 Gbit/s over a few hundred metres, and one fibre type means one set of leads and connectors. The comparison in single-mode vs multimode fibre turns on reach, not price.
Connectors and polish
APC ferrules are green and cut at an 8 degree angle; UPC ferrules are blue and flat. Never mate the two, because the air gap adds reflection and loss. Keep APC at the ONT and choose LC/UPC inside for port density.
Bend radius, containment and loss
Glass does not snap when bent; it leaks light out of the cladding, and the loss appears as a mystery 3 dB that cleaning never removes. The figures below are working minimums, not published limits, and assume the cable is clipped rather than hanging free.
| Segment | Fibre and connector | Typical length | Working bend radius | Responsibility |
|---|
| Aerial drop | single-mode, SC/APC | 35 m | 30 mm | operator |
| ONT to router | single-mode, LC/UPC | 2 m | 20 mm | occupier |
| Riser to first floor | single-mode indoor, LC/UPC | 20 m | 30 mm | occupier |
| Shed or outbuilding | single-mode, LC/UPC | 40 m | 30 mm | occupier |
Loss adds up in the wrong places. Two mated pairs cost about 0.3 dB each with clean APC ferrules, a tight coil can cost 3 dB, and the cable itself contributes 0,035 dB over 100 m. That is why a rough coil matters more than the length of the run. A fibre patch cords guide is worth reading before ordering leads you cannot dress.
Practical scenarios
- Situation: an ONT in a hallway cupboard with no socket. Add a 13 A outlet within 1 m and leave 40 mm of clear space around the case for convection.
- Situation: a garden office 45 m from the ONT. Run single-mode indoor fibre in 20 mm conduit, which keeps the installed bend radius above 30 mm at every corner.
- Situation: a patch lead that has been unplugged ten times. Replace it rather than clean it: a 2 m LC/UPC lead costs less than the loss a scratched ferrule adds.
- Situation: a fibre run sharing a duct with mains cable. Keep 100 mm of separation where you can, and cross at right angles where you cannot.
FAQ
Can I extend the fibre drop myself?
No. The drop is the operator’s cable and its connector is part of their loss budget. Extending it means two extra mated pairs, a new splice or a coupler, and any fault on that side is chargeable. Ask for the ONT to be relocated instead, or run your own fibre from the ONT onwards.
Is fibre better than Ethernet inside a house?
Only where it solves a specific problem: runs beyond 100 m, a route that crosses earthed metal or a lightning-prone exterior wall, or a duct too crowded for another cable. For a 15 m run to a study, Cat 6a is cheaper, easier to terminate and carries 10GBASE-T to the full 100 m.
How tight can a fibre cable be coiled?
Treat 30 mm as the working minimum for installed single-mode cord and 20 mm for a patch lead inside a cabinet. Bend-insensitive fibre tolerates tighter coils, but the loss appears before the break does. A coil of 60 mm diameter, taped and clipped, is safe and easy to dress.