EtherCAT G Cable: Ten Times the Rate, Same Copper Questions
Quick answer / TL;DR: Short answer: EtherCAT G at 1 Gbps runs on shielded Cat5e or Cat6 and is more sensitive to termination quality than standard EtherCAT. EtherCAT G10 at 10 Gbps needs Cat6A and short segments. Both require the same shield bonding and grounding discipline, and mixing them into an existing 100 Mbps network requires a branch controller.
Three data families: USB carries power too, Ethernet spans buildings, fiber spans kilometers.EtherCAT G takes the same protocol and runs it ten times faster, and the first question everyone asks is whether the cable has to change. The answer is that it depends on which variant of G, and that the answer is less interesting than the shielding and grounding that were already wrong.
At 100 Mbps the physical layer tolerates a great deal of installation sloppiness, which is why so many machines run on cable that should not work. At 1 Gbps that tolerance disappears, and at 10 Gbps it disappears completely.
This article covers the two G variants, the cable each requires, and the migration problem of mixing gigabit segments into a 100 Mbps network.
Standard EtherCAT runs at 100 Mbps over 100BASE-TX. EtherCAT G raises the line rate to 1 Gbps and EtherCAT G10 to 10 Gbps, both introduced as extensions rather than replacements, so a network can contain segments at different rates.
The protocol behaviour is unchanged: frames are processed on the fly by each slave, and the topology can be line, ring or tree. What changes is the electrical margin available for installation error.
Cable Requirements by Variant
| Variant | Line rate | Physical layer | Minimum cable | Typical segment |
|---|
| EtherCAT | 100 Mbps | 100BASE-TX | Shielded Cat5e | 100 m |
| EtherCAT G | 1 Gbps | 1000BASE-T | Shielded Cat5e or Cat6 | 100 m |
| EtherCAT G10 | 10 Gbps | 10GBASE-T | Cat6A | Short, often 30 m or less |
The 100 metre channel limit applies at 1 Gbps, but the practical limit shrinks because the margin consumed by poor terminations is larger at higher rates. A link that ran at 100 Mbps with a marginal termination will not necessarily run at 1 Gbps.
Why the Installed Base Still Decides
Most machines in the field are 100 Mbps. Adding a gigabit segment means inserting a branch controller that bridges the rates, so the migration is a topology decision before it is a cable decision.
Where a machine is being designed new, specifying shielded Cat6 rather than Cat5e costs little and leaves the option open, because the same cable supports both rates.
Where Gigabit Changes the Diagnosis
At 100 Mbps a partially damaged pair usually causes a clean link failure, which is easy to find. At 1 Gbps the same damage can produce a link that trains, passes traffic and corrupts a frame occasionally, which presents as a working counter error on one axis.
- Certify the channel at the installed length rather than testing continuity
- Measure skew, because higher rates are less tolerant of pair-to-pair timing differences
- Bond the shield at both ends to a low-inductance earth, not through a pigtail
- Keep untwisted length at terminations to a minimum, which matters more at 1 Gbps than at 100 Mbps
- Verify the negotiated rate at each port after commissioning, because a device may fall back silently
Real-World Applications
A semiconductor handler needs a 250 microsecond cycle with more axes than 100 Mbps can carry. The design uses EtherCAT G on the segment with the highest device count and standard EtherCAT elsewhere, bridged by a branch controller at the cabinet boundary.
A printing press retrofit adds high-resolution inspection cameras to an existing EtherCAT line. The cameras do not run on EtherCAT; the segment is upgraded to G only where the added devices justify it, and the rest of the machine keeps its 100 Mbps cable because recabling the whole press is not economic.
A machine tool builder standardises on shielded Cat6 for every EtherCAT run, even though most builds run at 100 Mbps. The incremental cable cost is small and the same part number supports a G upgrade without a BOM change.
A packaging line with a ring topology uses G on the ring because a ring multiplies the frame traffic through each node. The cable is certified in the ring configuration rather than as individual runs, because the ring is what the frames traverse.
Standards and Verification
EtherCAT is specified in IEC 61158 and IEC 61784-2, with the EtherCAT Technology Group publishing the G and G10 extensions alongside conformance guidance. The copper is specified through ISO/IEC 11801 and TIA-568, so a G segment is certified with ordinary structured-cabling equipment.
Verification should include channel certification at the installed length, shield continuity end to end, skew measurement, and a check of the negotiated rate at every port. At gigabit rates a port that fell back to 100 Mbps is a finding, not a detail.
Record the certification against the segment rather than the cable, because a G segment is a topology unit and the useful comparison later is segment to segment.
Related reading: EtherCAT cable selection — blogs/news/ethercat-cable
Related reading: Industrial Ethernet cable selection — blogs/news/industrial-ethernet-cable
Related reading: Cat6A ethernet cable guide — blogs/news/cat6a-ethernet-cable-guide
A gigabit segment does not make the whole machine faster. The cycle time is set by the slowest segment and by the branch controller that bridges the rates, so upgrading cable without upgrading topology buys nothing.
Frequently Asked Questions
Does EtherCAT G need a different cable?
At 1 Gbps, shielded Cat5e or Cat6 is sufficient to 100 metres. At 10 Gbps, Cat6A is required and segment lengths are much shorter. Both need proper shield bonding.
Can I mix EtherCAT G and standard EtherCAT on one machine?
Yes, through a branch controller that bridges the rates. The segments remain electrically separate, which is also what keeps the faster segment's stricter requirements contained.
Why does a gigabit link fall back to 100 Mbps?
Usually a damaged pair, a marginal termination, or a cable that is not actually rated for the rate. Higher rates consume more margin, so faults that were invisible at 100 Mbps surface as a fallback.
Is Cat6 worth it if I only need 100 Mbps today?
Often yes. The cost difference against shielded Cat5e is small, and it removes the cable from the list of things to change if the machine is upgraded to G later.