Quick Answer / Summary: Use 75 ohm coax such as RG-59 or RG-6 with RCA plugs for S/PDIF and composite video. Keep S/PDIF runs under 10 m and composite runs under 30 m, and confirm the datasheet states 75 ohm with about 17 pF per foot. An audio patch cable runs 25 to 30 pF per foot with uncontrolled impedance, so a 1 m link may lock while a 5 m link fails. Check the cable, not the source.
Seventy-five ohms is a property of the cable and its termination, not of the RCA plug. A true 75 ohm coax with RCA ends carries S/PDIF at 0.5 V peak-to-peak and composite video at 1 V with controlled reflections. An ordinary audio patch cable is not 75 ohm, and the mismatch shows up as a rounded edge and jitter at the receiver. The rest is construction, limits and checks.
Why Audio Patch Cables Are Not 75 Ohm
Characteristic impedance follows conductor diameter, dielectric spacing and shield geometry. A 75 ohm video coax uses a 0.6 to 0.9 mm center conductor, a polyethylene dielectric and a close braid, giving about 17 pF per foot. An audio patch cable uses thin conductors and a spiral shield and lands near 25 to 30 pF per foot.
The RCA plug compounds the problem. Neither plug nor socket defines a controlled impedance transition, so even good coax loses return loss at the connector. At 6 MHz for composite video that is tolerable; at the 12.3 MHz frame rate of 192 kHz S/PDIF the discontinuity sits close to the signal band.
Capacitance and edge shape
Capacitance per unit length sets how fast the cable charges. An audio cable at 28 pF per foot presents about 65 percent more load per meter than a 17 pF per foot video coax, so the same driver produces a visibly slower edge.
Shield construction and coverage
Digital audio and video coax uses bonded foil plus braid, usually 95 percent coverage or better, with a drain wire. A spiral shield leaves gaps that behave as slots at high frequency, letting RF in and letting the edge radiate.
What an Impedance Mismatch Does to a Digital Edge
A reflection appears wherever impedance changes. At the plug the 75 ohm line meets an uncontrolled transition. A short run absorbs the reflection inside the transition time, so the edge only softens. A long run returns it late, as a notch in the waveform.
S/PDIF receivers slice at a fixed threshold and recover the clock from those same transitions. Ringing near the threshold moves the crossing point, which is jitter. Enough jitter and the receiver mutes or unlocks, so the failure is a dropout, not distortion.
Length limits in practice
Composite video at 6 MHz tolerates 30 m of RG-59 with RCA ends in most rooms, and RG-6 extends that. S/PDIF at 12.3 MHz is less forgiving: 10 m of true 75 ohm coax is a safe working limit, and past that cable quality decides whether the link locks.
Cable Types and Practical Runs
Impedance, capacitance and shield decide the usable run.
Terminating the RCA plug
Use a plug sized for the cable, not a universal body. The braid must be clamped under the shell barrel and the center conductor soldered to the pin. Exposed center conductor ahead of the pin adds inductance at the impedance step.
| Cable | Impedance | Capacitance | Practical run |
|---|
| Audio patch cord, RCA | 40-60 ohm, uncontrolled | 25-30 pF/ft | Line level only, under 1 m |
| RG-59, 75 ohm | 75 ohm | 17 pF/ft | S/PDIF to 10 m, composite to 30 m |
| RG-6, 75 ohm | 75 ohm | 16 pF/ft | Composite 30 m and longer |
| RG-179, 75 ohm | 75 ohm | 21 pF/ft | Rack jumpers under 3 m |
| Star quad, 110 ohm | 110 ohm | 12-20 pF/ft | Balanced analog, not S/PDIF |
Real Installations
Two cases where the cable, not the length, caused the fault.
Studio monitors dropping out at 96 kHz
A project studio fed two active monitors from an interface over 6 m cords built from microphone cable and RCA plugs. One channel dropped out at 96 kHz. The cable measured about 48 ohm and 26 pF per foot. Replacing it with RG-59 and solder-type RCA plugs removed the dropout, and hum fell once the shield was bonded at one end.
School video feed with a dark band
A school sent composite video from a media rack to classroom displays over existing RG-59 with crimp RCA ends. Two rooms showed a dark horizontal band. One crimp ring had not compressed the braid, and a TDR showed a dip 0.4 m from the plug. Re-terminating with a compression plug fixed both rooms.
Frequently Asked Questions
Can I use a regular RCA audio cable for S/PDIF?
For a short test only. An audio patch cable is not 75 ohm and carries 25 to 30 pF per foot, so a digital link may lock at 1 m and fail at 5 m.
Is RG-6 better than RG-59 for digital audio?
Both are 75 ohm. RG-6 has lower loss and a larger conductor, which helps beyond 10 m. For a rack jumper of 1 to 3 m, RG-59 or RG-179 is easier to dress.
What is the maximum length for coaxial S/PDIF?
About 10 m of true 75 ohm coax at 192 kHz. Lower sample rates and lower-loss cable extend that. Beyond it, convert to optical or insert a re-clocking distributor.
Does the RCA plug itself affect impedance?
Yes. No RCA plug holds 75 ohm through its body, so a small discontinuity always exists. A solder-type plug sized to the cable and a short signal path keep the reflection negligible.
Why does my digital coax pick up hum?
A spiral shield with low coverage passes low-frequency noise, and a shield bonded at both ends can create a ground loop. Use bonded foil plus braid and check that both chassis sit at the same potential.
Related resources: coaxial to RCA connector; digital coaxial cable; coaxial vs optical audio