Quick answer: An unbalanced signal is one conductor measured against ground, and a balanced signal is the difference between two conductors driven in opposite polarity. The balanced receiver subtracts the two, so the signal doubles and the noise that is common to both cancels. The rejection is quoted in decibels and it collapses when one leg is grounded or lifted.
Balanced vs Unbalanced Signal: What the Meter Shows
A balanced signal and an unbalanced signal differ in what the receiver measures, and the difference is visible on a meter. The unbalanced signal is one voltage against ground, and the balanced signal is the difference between two voltages that move in opposite directions. The second arrangement lets the receiver subtract the noise that both conductors picked up, which is the property the whole interface is built on. This guide covers the two signals, the common mode, the rejection figure, the faults that break it, and the two tests that show whether it is working.
The Two Signals
The two signals are the same audio carried in two different electrical arrangements, and the arrangement decides what the receiver can do with the noise. The unbalanced signal is a voltage between one conductor and the ground, so any noise that appears on that conductor arrives as signal. The balanced signal is a voltage between two conductors, neither of which is the reference, so the receiver compares them and the noise that appears on both is subtracted away. The audio is identical and the difference is the arithmetic.
Single-Ended Against Ground
The single-ended signal is the one that a voltmeter reads between the centre contact and the shell, and it is the signal the consumer interface uses. The conductor carries the audio, the shell carries the return, and the noise that the cable picks up adds to the audio because it appears on the same conductor. The receiver has no second copy to compare against, so the noise is passed on. The arrangement is simple and it works where the noise is small.
Differential Across the Pair
The differential signal is the one that a voltmeter reads between the two conductors of the pair, and neither of them is ground. The driver puts the audio on one conductor and the inverse on the other, so the difference is twice the audio and the sum is zero. The noise that the cable picks up appears equally on both conductors, so the difference carries it at zero and the sum carries it twice. The receiver takes the difference, which is why the noise cancels.
Common Mode and Rejection
The common mode is the part of the signal that is the same on both conductors, and the rejection is the receiver’s ability to ignore it. The noise induced by an external field is common mode, because the two conductors sit close together and the field reaches both. The receiver’s differential input amplifies the difference and rejects the common part, and the ratio of the two is the common-mode rejection ratio. The figure is quoted in decibels and it is the number that describes the interface.
What Common Mode Means
The common mode is the average of the two conductor voltages, and the differential mode is the difference between them. Any signal that appears on both conductors with the same amplitude and phase is common mode, and the noise from a mains cable, a dimmer, or a radio transmitter is common mode because the field reaches both conductors. The audio is differential, because the two conductors carry it in opposite phase. The receiver separates the two by subtraction.
The Decibel Figure
The rejection ratio is the gain applied to the differential signal divided by the gain applied to the common signal, expressed in decibels. A figure of eighty decibels means the common-mode noise appears at one ten-thousandth of the differential gain, which is a factor of ten thousand in voltage. The figure falls with frequency, because the two legs and the two amplifiers do not track perfectly as the frequency rises. The number is quoted at a frequency and it is meaningless without it.
What Breaks the Rejection
The rejection is easy to break, and the breaks are the common faults in an installation. Grounding one leg removes half the differential signal and with it the cancellation, because the receiver then compares a signal against a ground that carries the noise. Lifting the cold leg removes the same half and leaves the pair open. An adapter that ties the two legs together at one end turns the pair into a single conductor with a loop. Each fault has a signature on the meter.
The Unbalanced Adapter
The unbalanced adapter is the most common break, because it is the part that connects a balanced output to a consumer input. The adapter ties the cold leg to the shield, which is correct at the receiving end on a floating output and wrong on a ground-referenced one. In both cases the receiver reads one leg and the noise on that leg arrives as signal. The adapter is the right tool for the short run and the wrong one for the long run, and the difference is the noise.
The Pin 3 Lift
The pin three lift is the practice of disconnecting the cold leg at one end to cure a hum, and it works by accident rather than by design. The lift removes the loop that the shield and the cold leg formed, so the hum falls, and it also removes the differential signal, so the level drops by six decibels and the rejection goes with it. The correct fix for the loop is the transformer or the ground lift on the shield, not the signal leg.
Measuring It
The measurement takes a meter and two tests, and it settles the question faster than the listening. The first test reads the two legs against ground with a signal applied, and a balanced output shows equal and opposite voltages while an unbalanced one shows a signal on one leg and nothing on the other. The second test reads the difference between the legs, which should be twice the single-leg figure. The two readings together describe the connection.
The Meter Test
The meter test uses a sine wave at a few hundred hertz and a multimeter on the alternating current range. The hot leg to ground reads the single-ended level, the cold leg to ground reads the same level with the opposite phase, and the two legs together read twice the level. The balanced output shows the three readings; the unbalanced output shows the first and nothing on the second. The test is safe at the line level and it needs a meter with the range for a volt or two.
The Listening Test
The listening test is the mono sum, and it is the fastest check on the polarity. A recording with the two channels summed to mono cancels if one channel is inverted, and the cancellation is obvious as a thin or missing centre. The test catches the swapped leg that the wiring produces, and it catches the adapter that inverts one channel. The meter shows the level and the listening test shows the polarity, and the two together cover the wiring.
The Two Signals Side by Side
| Property | Unbalanced signal | Balanced signal | Measured how | Fault signature |
|---|
| Reference | Ground | The other conductor | Meter to ground | One leg dead |
| Audio on each leg | One conductor | Equal and opposite | Both legs to ground | Unequal readings |
| Noise | Passed to the receiver | Cancelled by subtraction | Difference reading | Hum that follows the cable |
| Level for the same source | 1x | 2x differential | Difference reading | 6 dB down with an adapter |
| Rejection | None | 80 to 100 dB typical | Common-mode test | Collapse at high frequency |
Real-World Application Scenarios
The long microphone line is the case the differential signal serves. The mic is a low level source, the cable runs thirty metres beside the mains, and the noise that the two conductors pick up cancels in the preamp’s differential input. The stage to the console is the second, where the same arithmetic keeps the residual hum below the programme. The short consumer run is the third, and there the unbalanced signal is adequate because the cable is a metre and the noise is small. The adapter into a consumer input is the fourth, and there the rejection is gone, which is why the hum appears when the run is long.
Related Guides on This Site
The related guides on this site cover the cable and the interface. The cable that carries the differential pair is set out at balanced XLR cable, the question of whether every XLR is balanced is at are all XLR cables balanced, and the length the rejection supports is at long XLR cable.
Frequently Asked Questions (FAQ)
Q: What is the difference between a balanced and an unbalanced signal?
A: The reference. The unbalanced signal is one voltage against ground, and the balanced signal is the difference between two conductors driven in opposite polarity. The audio is the same, and the balanced arrangement lets the receiver subtract the noise that both conductors picked up. The difference is the rejection rather than the sound.
Q: Does a balanced signal have twice the level?
A: It has twice the differential voltage for the same per-leg drive, because the two legs are equal and opposite. The receiver sees the difference, which is the sum of the two magnitudes. The level at the input is therefore six decibels higher than either leg alone, which is the reason the unbalanced adapter loses six decibels.
Q: What is common-mode rejection?
A: It is the ability of the differential input to ignore the signal that is the same on both conductors. The ratio of the differential gain to the common-mode gain is the rejection, quoted in decibels. A figure of eighty decibels means the common-mode noise arrives at one ten-thousandth of the signal gain, and the figure falls as the frequency rises.
Q: Why does lifting pin 3 stop the hum?
A: Because it breaks the loop that the shield and the cold leg formed, and the loop was the path the hum current used. The lift also removes the differential signal, so the level drops by six decibels and the rejection is gone. It works as a diagnostic and it is not the fix. The transformer or the shield lift is the correct answer.
Q: How do I test whether my cable is wired balanced?
A: Apply a sine wave at a few hundred hertz and read the two legs against ground with a meter. A balanced output shows the same level on both legs with opposite phase, and the difference between the legs is twice the single-leg figure. An unbalanced output shows a signal on one leg and nothing on the other. The mono sum is the listening version of the same test.