Quick answer: A balanced output drives two legs in anti-phase from a low impedance source, typically fifty to six hundred ohms, into an input of ten kilohms or more. The low impedance lets it drive a long cable, and the high input impedance keeps the level and the top end. The output may float or be ground-referenced, and that decides whether the cold leg can be tied to the shield.
Balanced Outputs: Impedance, Load and Long Cable
Balanced outputs are the sending end of the balanced connection, and their behaviour is set by two numbers and one design choice. The output impedance is low, typically fifty to six hundred ohms, and it is what lets the output drive a long cable without losing the top end. The load the input presents is high, ten kilohms or more, and the ratio between the two is what the bridging rule is about. The design choice is whether the output floats or is referenced to ground, and it decides how the shield is wired and whether an unbalanced adapter is safe. This guide covers the stage, the load, the cable, and the wiring mistakes.
The Output Stage
The output stage is a pair of amplifiers or a transformer, and either way it presents a low impedance to the cable. The low impedance is the property that makes the long run possible, because the cable capacitance and the source impedance form a low pass filter and a low source impedance puts the corner far above the audio band. The stage also sets the maximum level, which is the nominal plus the headroom, and the current it can deliver into the load. The two figures that matter at the connector are the impedance and the maximum level.
Impedance and the Divider
The output impedance and the input impedance form a voltage divider, and the loss is the ratio between them. A fifty ohm output into a ten kilohm input loses about a twentieth of a decibel, which is inaudible, and a six hundred ohm output into the same input loses a little more and is still inaudible. The rule that follows is the bridging rule: the input impedance should be at least ten times the output impedance. The divider is also the reason several inputs can be paralleled without a loss, up to the point where the combined impedance falls.
Floating Against Ground-Referenced
A floating output has neither leg tied to the chassis, and a ground-referenced output has the cold leg at ground potential. The floating design tolerates an unbalanced connection without a short, because the cold leg can be tied to ground at the receiving end and the stage adjusts. The ground-referenced design is simpler and it does not tolerate the tie, because the cold leg is already at ground and the output stage drives against it. The specification rarely says which, and the manual or the schematic is the reference.
The Load
The load the input presents is the other half of the interface, and it is deliberately high. A line input is ten kilohms or more, and a microphone input is one to two kilohms with a transformer or the electronic equivalent. The high impedance draws little current from the output, which keeps the stage in its linear region and the level stable. The load is also where the cable capacitance lands, so the input impedance and the cable capacitance together set the corner frequency at the receiving end.
The Bridging Rule
The bridging rule says the input impedance should be at least ten times the output impedance, and the practice is far beyond that ratio. A fifty ohm output into a ten kilohm input is a ratio of two hundred, which is why the level holds and the distortion does not rise. The rule matters when several inputs are paralleled, because ten inputs of ten kilohms present one kilohm and the ratio falls. The combined load is the number to check when the output feeds a distribution amplifier.
Paralleling Inputs
Paralleling inputs is common in a studio, where one output feeds several destinations. The combined impedance falls as the inputs add in parallel, and the level loss rises with the ratio. Ten inputs of ten kilohms give one kilohm, and a fifty ohm output into that load loses a tenth of a decibel, which is still inaudible. The problem appears with a high impedance output or a transformer output, where the paralleled load can pull the level down and the low frequency response with it.
Driving a Cable
The cable is the part that the output has to drive, and the two properties that matter are the capacitance and the rejection. The capacitance forms the low pass filter with the output impedance, and the balanced pair’s rejection carries the noise that the cable picks up. A low impedance output and a balanced pair together give the long run, and the length limit is where the capacitance takes the top end or the rejection runs out of margin. Both limits are far beyond the domestic run.
Capacitance and the Corner
The corner frequency is set by the output impedance and the cable capacitance, and it falls as either rises. A fifty ohm output driving a hundred metres of cable at fifty picofarads per metre sees five nanofarads, and the corner is at about six hundred kilohertz, far above the audio band. A ten kilohm source driving the same cable puts the corner at three kilohertz, which is inside the band and audible. The output impedance is the number that decides.
The Rejection Margin
The rejection margin is what the pair has left after the cable and the connectors take their share. A good output and a good input together reach eighty to a hundred decibels at the mains frequency, and the cable and the connectors reduce that to what the installation achieves. The margin is what keeps the residual hum below the programme, and it is the reason the balanced connection exists. The long run uses the margin, and the short run does not need it.
Wiring the Output
The wiring follows from the output design, and the two mistakes are common enough to be worth naming. The first is tying the cold leg to the shield on a ground-referenced output, which shorts the stage. The second is leaving the shield disconnected at both ends, which removes the electrostatic protection that the shield is for. The correct wiring keeps pin two hot and pin three cold, ties the shield at one end, and respects the design of the output.
The Shield and the Ground
The shield is tied at the source end in the standard practice, so the shield current has a path that does not run through the receiving chassis. The exception is the radio frequency case, where both ends are tied for the shield’s own sake. The ground lift switch on a direct box opens the shield connection at one end, and it is the tool for the loop that the tie creates. The shield is a screen and a return, and the two jobs are separated by where it is tied.
The Adapter Mistakes
The adapter mistakes are the ones that damage equipment. A balanced output to an unbalanced input needs the cold leg tied to the shield at the receiving end on a floating output, and it needs the same on a ground-referenced output that is designed for it. A bridged or floating output that is tied to ground at the receiving end can short one half of the stage. The rule is to know the output design before the adapter is used, and the manual is the source.
Balanced Output Against the Load
| Factor | Typical figure | Why it matters | Check |
|---|
| Output impedance | 50 to 600 ohms | Cable drive | Specification |
| Line input impedance | 10 kilohms or more | Bridging ratio | Input specification |
| Mic input impedance | 1 to 2 kilohms | Loading | Preamp specification |
| Maximum output level | Nominal plus 20 dB | Clipping point | Headroom figure |
| Cable capacitance | 30 to 60 pF per metre | Top end loss | Cable data |
| Shield tie | Source end only | Ground loop | Wiring practice |
Real-World Application Scenarios
The rack to the stage is the case the low output impedance serves. The console output drives eighty metres of multicore into the amplifier rack, and the corner frequency stays far above the audio band because the source is a few hundred ohms. The interface to the monitors is the second, where the output feeds two powered speakers through a short split and the paralleled load is still high. The distribution amplifier is the third, where one output feeds eight destinations and the combined impedance is the number to check. The consumer output into a pro input is the fourth, and there the high output impedance of the consumer device is the limit that the gain stage cannot fix.
Related Guides on This Site
The related guides on this site cover the cable and the level. The studio cable practice is set out at pro audio XLR cables guide, the cable families are compared at XLR cable selection, and the run length the output supports is at long XLR cable.
Frequently Asked Questions (FAQ)
Q: What is the output impedance of a balanced output?
A: Typically fifty to six hundred ohms, with the lower figures on the modern electronic stages and the higher ones on transformer outputs. The figure matters because it forms a divider with the input impedance and a filter with the cable capacitance. The low figure is what lets the output drive a long cable without losing the top end.
Q: Can I connect one balanced output to several inputs?
A: Yes, up to the point where the combined impedance loads the output. Ten inputs of ten kilohms present one kilohm, and a fifty ohm output drives that with a tenth of a decibel of loss. The caution is the transformer output, where the paralleled load can pull the level and the low frequency response down. The combined impedance is the number to check.
Q: What is a floating balanced output?
A: It is an output where neither leg is tied to the chassis, so the receiving end can tie one leg to ground without shorting the stage. The transformer output is inherently floating, and the cross-coupled electronic stage behaves the same way. The ground-referenced output is the simpler design and it does not tolerate the tie. The manual is the reference for which one a device has.
Q: Where should the shield be connected?
A: At the source end in the standard audio practice, so the shield current does not run through the receiving chassis. The receiving end is left open, and the ground lift switch on a direct box does the same job when the loop persists. The exception is the radio frequency case, where the shield is tied at both ends for its own effectiveness.
Q: Why does a balanced output lose level when I use an adapter?
A: Because the adapter reads one leg against ground rather than the difference between the two, which halves the amplitude and gives about six decibels of loss. The cross-coupled output compensates for the unbalanced load and the simple output does not. The loss is a level change rather than a fault, and the gain stage makes it up where the headroom allows.