Quick answer: Multimode fibre wire carries several light paths and is used inside buildings. OM3 reaches 300 m at 10G, OM4 reaches 400 m, and OM5 adds wider bandwidth for short-wave multiplexing. At 40G the distances fall to 100 m or 150 m. The transceiver and the installed grade set the limit, not the cable alone.
Multimode is cheaper to terminate and cheaper to drive than single mode, which is why it dominates within buildings. The catch is that reach depends on the grade, and a link that worked at 10G may not run at 40G on the same cable.

Grades and what they buy
OM3 and OM4
OM3 has a modal bandwidth that supports 10G to 300 m and 40G to 100 m. OM4 increases the bandwidth so 10G reaches 400 m and 40G reaches 150 m. The cable looks the same, so the grade is printed on the jacket and confirmed by the test report rather than by appearance.
OM5 and short-wave multiplexing
OM5 adds bandwidth at longer wavelengths, which allows several short-wave channels to be combined on one fibre. That reduces fibre count in a backbone. It costs more and only pays back where the transceivers support the technique, so it is a design decision rather than a default upgrade.
Distance by speed
| Grade | 1G | 10G | 40G |
|---|
| OM1 | 300 m | 33 m | Not supported |
| OM2 | 600 m | 82 m | Not supported |
| OM3 | 1000 m | 300 m | 100 m |
| OM4 | 1000 m | 400 m | 150 m |
Choosing and installing
Match the transceiver
A 10G SR transceiver is designed for multimode at 850 nm. A single mode transceiver on the same cable will not link, and a multimode transceiver on single mode cable does not either. Confirm the optic part number before ordering cable, and keep a record of the grade installed so future upgrades are planned rather than guessed.
Bend radius and pulling tension
Multimode fibre is glass and does not forgive a tight bend. Keep the radius above the manufacturer minimum, use pulling grips rather than tying to the jacket, and never exceed the tensile rating. A bend that reduces light is invisible until the link budget is marginal, which usually happens at the far end of the run.
Upgrading an existing multimode plant
Reuse the cable where the grade allows
An installed OM3 backbone supports 10G to 300 m, which covers most buildings. Upgrading to 40G may not need new cable if the runs are short enough and the optics support the grade. Test the existing link first: a clean OM3 run often delivers more than the nominal distance because the standard is conservative.
When to move to single mode
Runs beyond the multimode limit, links between buildings, and any route where the cable cannot be replaced later are reasons to choose single mode. The optics cost more at low speeds and less at high speeds, so the decision usually favours single mode for anything that must last a decade.
Record the grade on the patch panel label, not only on the cable jacket. Jackets fade and get painted over, and the next technician will assume the cheapest grade unless told otherwise. A label reading OM4 tells everyone what the link can support and prevents a future upgrade from being planned around the wrong fibre.
If the site plans a 40G upgrade within five years, install OM4 now rather than OM3, because the difference in cable price is small compared with reopening a duct or a ceiling void later.
If the link crosses between buildings, check the earth potential difference before pulling copper, since fibre removes the problem entirely and is often the cheaper answer once protectors are included.
If the fibre is being pulled into a duct with existing cables, inspect the duct for sharp edges first, because a damaged jacket on multimode fibre lets water in and the resulting loss appears at the far end of the run rather than where the damage happened.
Practical scenarios
- Building backbone: OM4 between floors, leaving headroom for a later 40G upgrade.
- Data closet links: OM3 patch leads for short 10G runs where 300 m is ample.
- Campus link at 500 m: single mode rather than multimode, since OM4 stops at 400 m for 10G.
- Industrial cabinet: armoured multimode where rodents or vibration are a risk.
FAQ
Can I run 10G over OM1 or OM2?
Only over very short distances, and often not at all. Use OM3 or OM4 for building runs.
Does multimode work with single mode transceivers?
No. The core size and wavelength differ, so the link will not come up.
Is OM5 worth the extra cost?
Only when the design uses short-wave multiplexing and the optics support it. Otherwise OM4 gives the same reach for less.