GG45 Connector: Cat7 Performance Without Changing Your Patch Cords
Quick answer / TL;DR: Short answer: GG45 is a Cat7 connector standardised in IEC 60603-7-7 that accepts ordinary RJ45 plugs while adding four outer contacts for 600 MHz operation. It lets a building keep RJ45 patch cords for legacy equipment and still achieve a compliant Cat7 channel with GG45-to-GG45 cords. It costs more than RJ45 and is far less available outside Europe, so confirm supply before specifying it.
The Cat7 connector problem: the cable is rated, the familiar plug is not.If you buy Cat7 cable, the connector decides whether you have a Cat7 channel at all. Ordinary RJ45 is not specified above Cat6A. GG45 is one of the two interfaces ISO recognises for Cat7, and its distinguishing feature is that it still accepts a standard RJ45 plug.
That backward compatibility is the reason GG45 wins most Cat7 projects. The alternative, TERA, performs at least as well but requires different patch cords throughout, which turns a cable upgrade into a full end-to-end replacement.
How a Connector Can Be Both GG45 and RJ45
The GG45 outlet has two sets of contacts. The inner eight are positioned exactly like an RJ45 jack, so any RJ45 plug inserted mates with them in the conventional pin arrangement. Four additional contacts sit on the outer edge of the interface, in the corners of the opening.
A GG45 plug is shaped so that when it is inserted, it engages the outer contacts and, in the Cat7 position, the signal is routed to them rather than to the inner eight. That arrangement gives each pair more physical separation and less coupling, which is what allows 600 MHz.
| Interface | Standard | Max frequency | Accepts RJ45 plug | Cat7 channel compliant |
|---|
| RJ45 | IEC 60603-7 | 500 MHz class | yes | no | GG45 | IEC 60603-7-7 | 600 MHz | yes | yes, with GG45 patch cords | TERA | IEC 60603-7-71 | 600 MHz, 1200 MHz for Cat7A | no | yes, with TERA patch cords |
The Two Modes and What They Mean for a Buyer
When an RJ45 plug is inserted, the outlet behaves as an RJ45 jack and the channel performance falls back to the RJ45 limit. When a GG45 plug is inserted, the outer contacts engage and the channel can reach Cat7 performance.
This is the practical advantage and also the most common misunderstanding. A GG45 outlet does not make an RJ45 patch cord into a Cat7 link. It simply means the outlet does not have to be replaced when legacy equipment is connected. The Cat7 channel only exists when both ends and both cords are GG45.
- Legacy device: RJ45 cord into GG45 outlet, works at RJ45 performance
- Cat7 link: GG45 cord into GG45 outlet at both ends, 600 MHz channel
- Mixed: GG45 outlet with RJ45 cord at one end is an RJ45 channel, not Cat7
- Document which outlets are used in which mode, or acceptance testing becomes ambiguous
Cost and Availability Reality
GG45 is a Nexans-developed interface and licensing has historically been narrower than RJ45. Availability is good in France, Germany, Benelux and the Nordics, and thin elsewhere. In North America it is effectively a special order.
| Item | RJ45 Cat6A | GG45 Cat7 |
|---|
| Outlet | widely stocked | special order outside Europe | Patch cord | commodity | limited brands | Patch panel | commodity | vendor-specific | Lead time | days | weeks | Price per outlet | baseline | 2 to 4 times baseline |
The cost multiplier is on the connector, not the cable, and it applies to every port in the building. A 500-outlet Cat7 project can spend more on GG45 outlets and cords than on the cable itself. That is the number to put in front of a client before the specification is fixed.
Real-World Applications
European building projects that specify Cat7
Public sector, healthcare and education specifications in continental Europe sometimes name Cat7 as a category without naming a connector. GG45 is the pragmatic answer because it satisfies the category and does not force every printer and access point onto a new cord type.
Retrofits where endpoints cannot change
In an occupied building with hundreds of devices already cabled with RJ45, a Cat7 backbone with GG45 outlets lets the structured cabling be upgraded while endpoints stay untouched. TERA in the same situation would require replacing every patch cord at cutover.
Laboratories moving to 10GBASE-T and beyond
Where the cabling has to hold margin for future standards within 600 MHz, GG45 gives the headroom and keeps instrument connections standard. The outlet accepts whatever RJ45 the instrument has, while the permanent link stays Cat7.
Where GG45 is the wrong choice
Projects outside Europe with no Cat7 mandate, where availability alone makes it impractical. Also projects where the actual requirement is 10GBASE-T at 100 m, which Cat6A satisfies at a fraction of the outlet cost.
Related reading: Cat7 cable selection and the 600 MHz limit — blogs/news/cat7-f-ftp-cable
Related reading: Cat7 building and connector practice — blogs/news/cat7-shielded-buying
Standards and Verification
GG45 is standardised in IEC 60603-7-7. Cat7 channels are defined in ISO/IEC 11801-1 at 600 MHz. There is no TIA category for Cat7, so a North American project using GG45 is working to ISO, and the acceptance documentation should say so explicitly.
Ask the supplier for a channel test report at 600 MHz that names the GG45 outlet and the GG45 patch cord models used. A report produced with RJ45 cords on the same outlets is a Cat6A report and should not be presented as Cat7 evidence.
On site, verify mating compatibility before bulk termination: insert one RJ45 plug and one GG45 plug into sample outlets and confirm both engage cleanly. Interface tolerance problems show up in the first ten outlets or not at all, and finding them after 500 terminations is expensive.
GG45 outlets usually bond the cable shield through the outlet body, which removes the separate bonding step that plagues shielded RJ45 work. Confirm the outlet provides a 360 degree bond and that the panel or faceplate does not interrupt it.
Frequently Asked Questions
Can I plug a normal RJ45 cable into a GG45 outlet?
Yes. That is the defining feature of GG45. The outlet accepts a standard RJ45 plug and operates at RJ45-level performance. You only get Cat7 performance when both ends and both patch cords are GG45.
Is GG45 better than TERA?
They reach the same 600 MHz and both are ISO-recognised Cat7 interfaces. GG45 is backward compatible with RJ45, which matters in retrofits. TERA has a different contact geometry and is used where higher categories or specific vendor ecosystems require it.
Do I need GG45 patch cords for a Cat7 channel?
Yes. A GG45 outlet with an RJ45 patch cord gives an RJ45 channel. The Cat7 channel requires GG45-to-GG45 cords so the outer contacts are engaged at both ends.
Is GG45 available in the United States?
Rarely from stock. It is a special order in North America, with lead times measured in weeks and limited brand choice. If the project is in the US, confirm supply and price before the specification is issued.
Does GG45 work with Cat6A cable?
Physically yes, and it will perform at least as well as an RJ45 assembly. There is little reason to pay the premium unless the cable is Cat7 or the project requires the higher interface headroom.
Sourcing cables for a project, a store, or a private-label line? Contact our B2B sales team for specifications, certification evidence, and volume terms – FOB and CIF options available. Request a quote or sample.