100 ft RG6 Coax: What the Length Costs in dB
Quick answer / TL;DR: Short answer: RG6 loses roughly 1.5 to 2 dB per 100 ft at 100 MHz, about 5 to 6 dB at 1 GHz and more at satellite IF frequencies. Use quad-shield for noisy routes, compression connectors rather than twist-on, and count every splitter at 3.5 dB or more. On a marginal satellite link, keep the run short or use RG11.
Three coaxial families: BNC for CCTV, F-type for TV, N for RF – each with its impedance.RG6 is the standard drop cable for satellite, cable television and MoCA. At 100 ft its attenuation is modest at low frequencies and significant at satellite intermediate frequencies.
Knowing the loss per band tells you whether a splitter or a longer run will push a receiver over the edge.
Attenuation by Frequency
| Frequency | Approximate loss per 100 ft | Typical service |
|---|
| 100 MHz | 1.5 to 2 dB | FM and low VHF |
| 500 MHz | 3.5 to 4 dB | CATV mid-band |
| 1 GHz | 5 to 6 dB | CATV upper band |
| 2 GHz | 8 dB and up | Satellite IF |
The figures are typical rather than guaranteed; cable construction and copper-clad centre conductors change them.
Shielding and Connectors
- Quad shield for routes near mains or transmitters
- Compression F connectors with a proper tool
- Avoid twist-on connectors
- Weatherproof boots outdoors
- No sharp bends at the wall entry
Twist-on connectors are the single largest cause of ingress in domestic installations, because the shield contact is not gas-tight.
Real-World Applications
A cable modem 100 ft from the entry point needs the run plus splitter loss calculated against the modem's operating window. A MoCA network over the same cable tolerates the loss but is sensitive to poor shielding, because the signal shares the cable with television services.
Standards and Verification
| Reference | Relevance |
|---|
| SCTE | Coaxial distribution practice |
| IEC 61196 | Coaxial cable specification |
| MoCA | In-home coax networking |
Attenuation for a specific cable is not provided in the knowledge base. Use the manufacturer's published curve.
Practical Notes
Measure signal level at the device, not at the entry. The number that matters is the one at the receiver.
Related reading: rg6 cable — blogs/news/rg6-cable
Related reading: coax cable digital — blogs/news/coax-cable-digital
Frequently Asked Questions
How much loss at 100 ft?
About 5 to 6 dB at 1 GHz.
Quad shield or standard?
Quad for noisy routes; standard is fine otherwise.
Does it work for MoCA?
Yes, with good shielding and no splitters in the path.
Sourcing cables for a project, a store, or a private-label line? Contact our B2B sales team for specifications, certification evidence, and volume terms – FOB and CIF options available. Request a quote or sample.