100 ft Coaxial Cable: The Loss Budget Again
Quick answer / TL;DR: Short answer: RG6 loses roughly 5 to 6 dB at 1 GHz over 100 ft and more at satellite IF. RG11 loses about a third less. Measure the signal at the entry before deciding: an amplifier helps only if the source has adequate level and quality, and it makes a noisy signal worse.
Three coaxial families: BNC for CCTV, F-type for TV, N for RF – each with its impedance.One hundred feet is about thirty metres, which is where RG6 loss becomes a design factor rather than a rounding error.
Whether that matters depends on the service and on how much signal arrives at the entry point.
Loss Comparison
| Cable | Loss at 1 GHz per 100 ft | Note |
|---|
| RG6 | 5 to 6 dB | Standard drop |
| RG11 | 3 to 4 dB | Larger, stiffer |
| RG59 | 8 dB and up | Short runs only |
The figures are typical rather than guaranteed, and copper-clad conductors perform worse than solid copper.
Amplifier or Not
- Amplify only when the input signal is clean
- Never amplify a noisy signal
- Place the amplifier as close to the source as possible
- Count splitter loss before adding an amplifier
- Keep amplifiers out of satellite runs unless designed for it
The satellite point is specific: satellite distribution uses different amplifiers and pass-through requirements, and a cable TV amplifier in that path usually breaks the link.
Real-World Applications
A modem at the end of 30 m of RG6 may need nothing at all if the entry level is high. A television at the end of the same run plus two splitters may need RG11 rather than an amplifier.
Standards and Verification
| Reference | Relevance |
|---|
| IEC 61196 | Coaxial cable |
| SCTE | Distribution practice |
| IEC 61169 | RF connectors |
Signal levels at a specific address are not provided in the knowledge base. Measure at the entry and at the outlet.
Practical Notes
Write the measured level on the wall plate label. It saves the next technician a trip to the van.
Related reading: coax cable — blogs/news/coax-cable
Related reading: 3 ft coaxial cable — blogs/news/3-ft-coaxial-cable
Related reading: xlr cable 100 ft — blogs/news/xlr-cable-100-ft
Frequently Asked Questions
Is 100 ft too long?
No, but loss becomes significant at high frequency.
Does RG11 help?
Yes, about a third less loss.
Should I amplify?
Only if the incoming signal is clean.
Sourcing cables for a project, a store, or a private-label line? Contact our B2B sales team for specifications, certification evidence, and volume terms – FOB and CIF options available. Request a quote or sample.