RG6 vs RG59: Loss and Bandwidth Decide
Quick answer / TL;DR: Short answer: use RG6 for satellite, cable TV, MoCA and any run over about 15 m. Use RG59 for short analogue baseband video and legacy CCTV where flexibility matters. RG6 loses roughly half as much per 100 ft at 1 GHz, which is the difference between a marginal link and a working one.
Three coaxial families: BNC for CCTV, F-type for TV, N for RF – each with its impedance.RG6 and RG59 look alike and are not interchangeable at high frequency. RG6 has a larger centre conductor and lower loss; RG59 is thinner, more flexible and cheaper.
The choice comes down to bandwidth and run length, not to brand or price.
Construction and Loss
| Property | RG6 | RG59 |
|---|
| Centre conductor | 18 AWG | 20 to 22 AWG |
| Impedance | 75 ohm | 75 ohm |
| Loss at 1 GHz, per 100 ft | 5 to 6 dB | 8 to 10 dB |
| Usable bandwidth | About 3 GHz | About 1.5 GHz |
Both are 75 ohm, so a mismatch is not the issue. The difference is attenuation at frequency, which is what satellite intermediate frequencies punish.
Where Each Belongs
- RG6: satellite IF, CATV, MoCA, long CCTV runs
- RG59: short composite video, legacy analogue CCTV
- Both: compression F connectors sized to the cable
- Neither: audio, where impedance and shielding differ
The connector point matters: an RG59 connector on RG6 cable makes a loose fit that passes a quick test and fails outdoors.
Real-World Applications
A satellite receiver 25 m from the dish needs RG6 throughout, because the IF band sits high enough that RG59 loss consumes the link margin. A four-camera analogue CCTV install with 8 m runs is fine on RG59 and easier to route.
Standards and Verification
| Reference | Relevance |
|---|
| IEC 61196 | Coaxial cable specification |
| SCTE | Distribution practice |
| IEC 61169 | RF connectors |
Measured loss for a specific cable is not provided in the knowledge base. Use the manufacturer's attenuation curve.
References
- IEC 61196-1, Coaxial communication cables – Generic specification
- SCTE operational practices for coaxial distribution
- IEC 61169, Radio-frequency connectors
Practical Notes
Measure signal at the receiver, not at the entry. RG6 versus RG59 shows up as a level difference at the far end.
Related reading: coax cable — blogs/news/coax-cable
Related reading: rg6 cable — blogs/news/rg6-cable
Related reading: rg59 cable — blogs/news/rg59-cable
Frequently Asked Questions
Can I use RG59 for satellite?
Not over any real distance. Loss is too high.
Are both 75 ohm?
Yes. The difference is conductor size and loss.
Which is more flexible?
RG59, which is why it survives tight cabinets.
Sourcing cables for a project, a store, or a private-label line? Contact our B2B sales team for specifications, certification evidence, and volume terms – FOB and CIF options available. Request a quote or sample.