Quick Answer / Summary: No. Every coaxial cable is built from the same four layers – center conductor, dielectric, shield, jacket – but the five choices made in those layers (impedance, conductor metal, shielding count, conductor size and installation rating) decide how far the signal travels and where the cable is allowed to go.

Pull three “coax cables” off a shelf – one for cable TV, one for CCTV, one for an antenna – and they look identical: a round cable with a shiny center pin. Electrically they are nothing alike. This article answers the question directly, then walks through the five differences that actually separate coaxial cables, and ends with the practical rule for choosing one without overpaying for specs you will never use.

Are All Coaxial Cables the Same? No – Here Are the 5 Differences

The Common Part: Four Layers, One Structure

Every coaxial cable shares the same construction: a center conductor carrying the signal, a dielectric spacer of fixed thickness, one or more metallic shields, and an outer jacket. That fixed geometry is what makes the impedance stable and the shielding effective – it is the whole reason coax works.

The differences are not in the structure but in the materials and dimensions chosen for each layer. A 75 ohm TV cable and a 50 ohm RF cable may have the same diameter and the same black jacket, yet the dielectric thickness differs by design, and with it the behaviour at the far end of the run.

Difference 1: Impedance (50 ohm vs 75 ohm)

Characteristic impedance is the first and most consequential split. 75 ohm minimises loss at video frequencies and is the standard for CATV, satellite, CCTV and component video. 50 ohm is the compromise between loss and power handling for RF work – antenna feeds, two-way radio, test equipment.

The impedance is set by the ratio of conductor diameter to dielectric thickness, so it is baked in at the factory and cannot be changed by an adapter. Mixing the two over a short patch is usually tolerable; mixing them over a long run creates reflections that show up as lost high channels or elevated VSWR.

Difference 2: Conductor and Shielding Materials

The center conductor can be solid copper, stranded copper, copper-clad steel (CCA) or silver-plated copper. Solid copper bends less and terminates more cleanly; stranded copper survives repeated movement; CCA is cheaper and stiffer but has higher skin-effect loss and is the weakest metal for crimp and solder joints.

The shielding story is similar. A single foil-and-braid shield is the consumer baseline. Double shield (foil plus braid, or two braids) adds attenuation of interference – the difference between a clean signal next to a motor and a noisy one. Quad-shield cable, with two foil layers and two braids, is the CATV standard in electrically noisy environments.

Difference 3: Gauge – the RG Number

The RG designation encodes conductor and dielectric size, and size is where the physics bites: a larger conductor and dielectric lose less per metre. RG11 beats RG6 on long runs, RG6 beats RG59 on modern cable-TV bandwidth, and RG174 is the low-loss mini-coax for short internal patching.

This is why “coax” is sold in sizes rather than as one product. A 50-metre satellite drop wants RG11 or at minimum a heavy RG6; a 1-metre bench patch is perfect in RG174. Buying the gauge for the run length – not the other way round – is the single cheapest way to keep a signal strong.

Difference 4: Installation Rating

The jacket and construction carry a flame and smoke rating: CM (communications), CMG (riser), CMR and CM (general-purpose), plus outdoor constructions with UV-resistant jackets and, for some, water-blocking fill. A CM-rated cable may not be legal in a building riser; an indoor cable will crack within a season outdoors.

Rating is the difference that shows up on an inspection and in a fire report, not on a signal meter. Match the rating to the route: in-wall, riser, attic, or outside. The same RG6 exists in several ratings, and the price spread is small compared with the cost of re-doing a run.

When “Just Any Coax” Is Actually Fine

None of this means every purchase needs an engineer. For a short indoor TV or antenna patch, any 75 ohm RG6 with F ends will perform identically in practice, and the five differences above will not change the picture. The differences start to matter the moment the run gets long, the frequency band gets high, the environment gets noisy, or the route goes through a wall.

So the honest answer to “are all coaxial cables the same” is: same family, different specifications – and the specifications only cost you when your application reaches for them. Choose impedance by the system, conductor by the environment, gauge by the distance, and rating by the route, and the rest of the shopping list takes care of itself.

How the Five Differences Show Up in Common Cables

CableImpedanceTypical ConductorShieldingGauge RoleRating Context
RG6 quad-shield (CATV)75 ohmSolid Cu or CCAQuadMain TV/satellite runIn-wall CM/CMR, outdoor
RG59 (legacy CCTV)75 ohmSolid Cu / CCASingle/doubleShort legacy dropsIndoor CM
RG11 (long runs)75 ohmSolid CuDouble+Long satellite/CATV dropsOutdoor, CMR riser
RG213 (RF)50 ohmSolid / stranded CuBraidedBase station, high powerOutdoor
RG174 (mini-coax)50 ohmStranded CuFoil + braidShort bench and internalIndoor equipment

Real-World Application Scenarios

A home installer feels all five differences at once: the outdoor satellite leg is RG11 or heavy RG6 in an outdoor-rated jacket (gauge and rating), the in-wall drop to each TV is CM-rated RG6 (rating), the legacy set-top feeding a CRT uses an RG59 patch (gauge), the cable running beside a LED driver wants quad shielding (shielding), and the 50 ohm test lead on the bench must never go into the 75 ohm TV tree (impedance). A CCTV contractor lives in the impedance-and-gauge choices, an RF technician in the impedance-and-power ones, and the consumer shopping for a TV cable mostly needs to check the impedance and the rating – the rest of the differences quietly do their job inside the specification.

Related reading: RG6 versus RG59 side by side; solid copper versus copper-clad steel; what quad shielding actually does; which coax ratings are legal in walls; 50 ohm versus 75 ohm coax.

Recommended Internal Resources

Editorial Note: Internal linking recommendation: support this comparison article from the RG6 vs RG59 guide, the CCA vs solid-copper explainer, the quad-shield guide and the in-wall ratings article; it is the natural hub for “difference between” style queries in the coax cluster.

Frequently Asked Questions (FAQ)

Q: Can I mix RG6 and RG59 coaxial cable in one run?

A: Physically yes with the right connectors, but RG59 has more loss, so the whole run is only as good as its weakest segment. For short legacy patches it is common and fine; for a new long run, standardise on RG6 (or RG11 for very long drops).

Q: Does the center conductor material affect the signal?

A: Yes, mainly at the top of the band. Copper-clad steel is acceptable for short consumer runs but loses more than solid or silver-plated copper and terminates less cleanly. For long runs, high channels or critical installations, specify solid copper.

Q: Is a thicker coaxial cable always better?

A: Thicker loses less per metre, so it extends maximum run length – but it is stiffer, costlier and needs bigger connectors. For a 2-metre patch, RG174 and RG6 perform indistinguishably; for a 60-metre drop, the larger gauge is the difference between a strong signal and a weak one.

Q: What rating do I need for in-wall coax?

A: At minimum a CM (communications) rated jacket; risers in multi-storey buildings typically require CMR or CMG. Outdoor runs need a UV-stable jacket and, for wet locations, a water-blocked construction. Check the printed rating, not the product name.