1000 Ft Cat6a: The Class EA Reel

Quick answer / TL;DR: Short answer: buy 1000 ft Cat6a for a floor or a small building where 10G is the requirement, and budget for the system around it – shielded jacks, panels with bonding, and channel testing. Cat6a is stiffer and heavier than Cat6: plan support, bend radius and two-person pulls. For gigabit-only sites, Cat6 is the cheaper correct answer.

High performance network cable cross-section with separator, foil, drain and 23 AWG labels
Headroom is built: separator, 23 AWG copper, foil and drain.

A 1000 ft Cat6a box supplies 305 metres of the 500 MHz category: enough for a floor of 10G drops, and heavy enough that handling becomes part of the project plan. It is the purchase that commits a site to Class EA, with everything that follows – shielded jacks, bonding, and per-port testing.

This is the 1000 ft Cat6a guide: the arithmetic, the physical handling, and the installation obligations the box implies.

The Arithmetic

The elementThe allowance
Route measuredHorizontal plus vertical
Service loopsAbout a metre per end
MarginTen percent – bend radius failures cost more
ThresholdAbout 280 m per box

The margin is higher than for Cat5e because a bend-radius failure on stiff cable means re-pulling, not splicing.

The System Obligations

The cable is the cheapest part of a Class EA system; the components and the testing are where the budget goes.

Handling

The factorThe practice
WeightTwo people for a full-height pull
Bend radiusLarger than Cat6, checked at every corner
SupportClips or tray at code spacing
PayoutBox upright, through the hole

The handling rules exist because Cat6a does not recover from a bad pull the way a lighter cable might.

Standards and Verification

The referenceThe relevance
TIA-568.2-DCategory 6A
ISO/IEC 11801-1Class EA
IEEE 802.3an10GBASE-T
Field testChannel test at Class EA

Per-SKU reel lengths are not provided in the knowledge base. Standard boxes apply; confirm the print and the footage marker on delivery.

Real-World Applications

The studio floor

A post-production floor with 10G to every desk: one 1000 ft box, shielded panels bonded, every port tested at Class EA – the class documented per link.

The single-box overrun

A floor measured at 300 m: the box ran out on the last two drops. A second box ordered – the measurement had excluded the riser height.

The unbalanced system

Cat6a cable with Cat6 jacks left in place: every link tested at Category 6. The jacks replaced – the box had been the right purchase with the wrong system around it.

Related reading: The category these boxes supply — blogs/news/cat6a-cable-spec

Related reading: The 500 ft Cat6 alternative — blogs/news/cat6-500ft-box

Frequently Asked Questions

How many drops does 1000 ft of Cat6a cover?

Roughly 20-25 at 10G with normal routes and loops.

Is Cat6a harder to install?

Yes: heavier, stiffer and slower to terminate.

What else does Class EA require?

Shielded jacks, bonded panels, Cat6a cords and per-port channel testing.

Do I need Cat6a for gigabit?

No – Cat6 is cheaper and sufficient.

Sourcing cables for a project, a store, or a private-label line? Contact our B2B sales team for specifications, certification evidence, and volume terms – FOB and CIF options available. Request a quote or sample.