Quick Answer: A 100 ft (30.5 m) run of standard RG6 loses about 2.1 dB at 100 MHz and roughly 7 dB at 1000 MHz, which is fine for cable TV, satellite IF and 75 ohm digital audio, but marginal for full-band satellite distribution above 2150 MHz. Stay under 150 ft (45 m) per drop, use quad-shield RG6 wherever the cable shares a stud bay with mains wiring, and move to RG11 past that distance. Terminate with compression F connectors only.
Loss, not length, is the number that decides whether a 100 ft reel works. RG6 is a 75 ohm coaxial cable with an 18 AWG copper-clad steel centre conductor and a foamed polyethylene dielectric, and its attenuation rises almost with the square root of frequency. That single relationship explains why the same drum of cable is generous for a TV outlet and tight for a satellite multiswitch feed.
What 100 feet costs in signal
Published attenuation figures for RG6 with a 60 percent braid sit near 1.6 dB per 100 ft at 55 MHz, 2.1 dB at 100 MHz and 7.0 dB at 1000 MHz. Add a wall plate, two connectors and a splitter and the practical figure is 1 to 1.5 dB worse than the bare cable number. Digital cable and satellite receivers tolerate a total loss of roughly 20 to 25 dB at the highest carrier they use, so 100 ft of RG6 leaves most of that budget intact at 1000 MHz and almost none of it at 3000 MHz.
For a 75 ohm digital audio feed the same cable is heavily over-specified. A coaxial cable carrying S/PDIF at 192 kHz needs bandwidth in the low tens of MHz, and a 100 ft length adds only a fraction of a dB across that band, which is why the same reel serves both a TV outlet and a digital audio run without argument.
Comparing the three grades that fit a 100 ft reel
| Frequency | RG6, 60% braid | RG6 quad shield | RG11 | Typical use |
|---|
| 55 MHz | 1.6 dB | 1.7 dB | 1.0 dB | Cable TV return path |
| 100 MHz | 2.1 dB | 2.2 dB | 1.3 dB | FM and digital audio |
| 250 MHz | 3.4 dB | 3.5 dB | 2.1 dB | Cable TV forward band |
| 1000 MHz | 7.0 dB | 7.2 dB | 4.3 dB | DOCSIS and MoCA |
| 2150 MHz | 10.6 dB | 10.9 dB | 6.5 dB | Satellite IF |
Figures are typical published values for bare copper conductor cable at room temperature and are a design aid, not a guarantee for a specific reel. Quad shield costs about 0.1 to 0.3 dB of extra loss over the same length and buys 20 to 30 dB of screening against ingress.
Where RG11 earns its price
Long service drops
Past 150 ft (45 m) the loss gap matters more than the stiffness. RG11 at 2150 MHz loses 6.5 dB per 100 ft against 10.6 dB for RG6, so a 200 ft (61 m) satellite feed saves roughly 8 dB by changing grade. RG11 has a 14 AWG centre conductor and a 0.405 in (10.3 mm) jacket, so it needs a larger wall plate opening and a wider bend radius of about 4 in (100 mm).
Short patch and jumper lengths
Below about 6 ft the grade is irrelevant and flexibility decides. A moulded coaxial cable 15 ft jumper in the same 75 ohm family handles the link between a wall plate and a set-top box without introducing a second connector type at the device end, and a short coaxial cable 3ft assembly keeps a rack tidy where the run is only a shelf gap.
Connectors, terminators and earth bonding
Use compression F connectors matched to the cable’s actual dielectric diameter; a screw-on connector that fits two cable types fits neither well and produces a return loss worse than 10 dB at 1 GHz. Fit a 75 ohm terminator on every unused splitter port. An open port reflects energy back down the line, which shows up as sparkle on some channels and as packet errors on a MoCA link. Bond the cable shield to the building earthing electrode at the point of entry with a listed ground block, and keep that bond separate from any equipment earth inside the room.
Any cable feeding digital audio or a data carrier over coax benefits from the same discipline, since a loose shield braid turns the run into an aerial for mains hum: see the notes on digital coaxial cable for the connector and shield details that matter at line level.
US installation rules that change the answer
Inside a stud wall the cable must carry a CL2 or better rating, and in a plenum return ceiling it must be CMP. Standard RG6 with a PVC jacket is CL2 and stops at the wall cavity; running it through an air handler space is a code failure regardless of how good the loss figure is. Support the cable every 4 ft (1.2 m) and within 12 in (300 mm) of each box, keep it 2 in (50 mm) clear of mains cable where the two run parallel, and cross at 90 degrees where they must meet.
Practical scenarios
- Situation: A single-family house needs four TV outlets from one service entry, longest run 120 ft (36.6 m). Use a four-way splitter with 7 dB per port, RG6 quad shield on all four drops, and check the receive level at the far outlet: anything below minus 12 dBmV at the highest channel points to a drop amplifier rather than thicker cable.
- Situation: A satellite dish sits 210 ft (64 m) from the receiver. Move to RG11 for the whole run, allow 13.6 dB at 2150 MHz, and confirm the receiver’s acceptable window before cutting; splicing RG6 onto the end adds two connectors and 0.4 dB for no benefit.
- Situation: A studio monitor feed runs 100 ft beside dimmer cabling. Fit quad shield and a ferrite at the source end, then measure hum with the dimmer at 50 percent; residual hum above minus 60 dBFS means the shield bond, not the cable grade, is the fault.
- Situation: A warehouse office is added after the coax was pulled. Do not convert the RG6 to Ethernet with passive baluns; a 100 ft coax pair will not hold 1000BASE-T. Pull Cat 6 alongside and keep the coax for the TV feed it was sized for.
FAQ
Can 100 ft of RG6 carry 4K satellite TV?
Yes, within limits. A 4K receiver typically needs a carrier near 2150 MHz, where 100 ft of RG6 loses about 10.6 dB. That fits inside the usual 20 to 25 dB budget once splitter loss is counted, but a two-way split adds 4 dB and leaves very little headroom.
Does a longer cable always mean a weaker picture?
For analogue video, yes, as visible grain. For digital carriers the picture stays perfect until the error correction runs out and then fails suddenly. That cliff is why a run that looks fine for a year can drop out when a splitter is added or the temperature rises.
Is copper-clad steel conductor a problem?
Only for direct current and for bending. Copper-clad steel is standard in RG6 and has the same radio frequency loss as solid copper at these lengths. It is stiffer and it will not carry power over coax as far, which matters for satellite line power.